Professional chimney service
Carney Chimney Pros

What the camera saw in your flue, and what fixes it

Price the repairs on your report

Written quote before any work
Photos in every report
Terms explained in plain words
Published prices for common visits
NFPA 211 inspection levels
Based in Tustin
Written quote before any work
Photos in every report
Terms explained in plain words
Published prices for common visits
NFPA 211 inspection levels
Based in Tustin

One frame from a flue camera

The screen shows a square clay tunnel, lit from the camera's own lamp, with a distance counter in the corner reading 11 feet. Halfway up the frame a thin dark line runs straight down one wall of the tile: a vertical crack. Where this tile meets the next one, the mortar joint has a gap you can see daylight through on a sunny day. Below that, the tile surface is coated in a black, shiny layer that looks like wet paint.

Three findings in one picture. The crack and the open joint mean the flue can no longer hold heat and smoke inside its walls. The shiny layer is glazed creosote, the hardest form of wood smoke residue, which burns hot if it ever catches. Most flue repairs on Tustin houses start from a frame like this one.

Cracked tiles and open joints

Clay flue tiles crack from age, from a past chimney fire and from earthquakes; the 1994 quake and the Whittier Narrows quake of 1987 left plenty of Southern California flues in that state without a single brick visibly out of place. A tile that has cracked cannot be made whole from inside.

The usual fix is a liner, a new continuous flue set inside the old one. For most fireplaces and stoves that means a stainless steel pipe sized to the appliance, run from the firebox or stove to the top and capped. Some masonry flues suit a cast-in-place liner instead, where a mix is formed inside the old flue. The camera footage and the appliance decide which one fits.

A flue with no liner at all

Some older brick chimneys were built with no tile lining. Smoke runs against bare brick and mortar, which the codes have not accepted for a long time. A camera shows rough brick and mortar joints where tiles should be.

These chimneys need a liner before any fire is lit. If you plan to switch to gas at the same time, a sealed gas insert brings its own liner to the top of the chimney, so the two jobs become one.

What the top of the chimney needs

A new liner is wasted if rain still gets in from above. The report usually pairs flue findings with a few items on the roof: a missing or rusted cap, a crown that has cracked, flashing that has lifted, or a wide chimney with no diverter on its uphill side. Those are listed below with their prices where we publish one.

Usual repairs and their prices

These are the fixes that come up most with flue findings and have a published price on this site. The cap is the exception: it is quoted after we measure. Where your report lists something else, the next note explains how it is priced.

Camera inspection of the full flue
$380
Water entry traced and stopped
$540 to $3,250
Sloped roof diverter (a cricket) on its own
$435 to $980
Diverter together with new metal at the roof joint
$650 to $1,600
Sealed gas heater set into your current fireplace opening
$2,700 to $5,400
Rain and spark cap over the flue opening
Quoted after we measure

Relining, crown work, damper repair, chase covers and flashing on its own have no published price. Each gets a written quote once the footage and the roof have been seen.

Questions about flue repairs

Can a sweep remove glazed creosote?

A normal brush does little to it. Glazed deposits need heavier removal work, and on a cracked flue they often come out as part of the relining job. The quote says which approach applies.

Do I need a liner if I only burn gas?

Gas exhaust still has to leave the house in a sound, properly sized flue. A cracked or oversized flue can let it cool and condense, which corrodes the flue and slows the draft. The report says whether yours needs one.

Does relining need a city permit?

Many cities ask for one on liner and appliance work. We say on the quote whether we expect a permit for your job.

Will the camera be run again after the work?

If you want a recorded check of the new liner, a second camera run can be added. It is useful when a buyer or lender asks for proof the finding was fixed.

Turn a failed report into a repair list

Use the contact page to tell us which findings your report shows. We reply with the repairs they need and a written quote for each.

Call (657) 233-4418
Call (657) 233-4418